Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.602
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 276, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600475

RESUMO

BACKGROUND: Traditional total hip arthroplasty (THA) using the direct anterior approach (DAA) requires a hip extension. This study aimed to compare the clinical outcomes of patients undergoing THA with DAA using either the no hip extension (NHE) or the traditional hip extension (THE) strategy. METHODS: A retrospective analysis of demographics, clinical and radiological outcomes, and occurrence of complications was performed using data from 123 patients treated between January 2020 and November 2021. The patients were categorised into two groups: NHE (84 patients) and THE (39 patients). RESULTS: The NHE group exhibited shorter operative time and had more male participants with higher ages. Comparable outcomes were observed in the visual analogue scale, Harris Hip, and Oxford Hip scores at the final follow-up. Furthermore, complications were observed in the NHE and THE groups, including two and one greater trochanteric fractures and three and one transfusions, respectively. CONCLUSIONS: Compared to the THE, employing the NHE strategy during THA with DAA in elderly and young female patients resulted in comparable clinical outcomes with several advantages, such as favourable surgical time. The NHE method also exhibited good safety and effectiveness. Therefore, the NHE strategy may be a favourable option for elderly and young female patients.


Assuntos
Artroplastia de Quadril , Humanos , Masculino , Feminino , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Resultado do Tratamento , Radiografia , Duração da Cirurgia
2.
J Arthroplasty ; 39(4): 991-996, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38661490

RESUMO

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.


Assuntos
Artroplastia de Quadril , Cabeça do Fêmur , Prótese de Quadril , Falha de Prótese , Reoperação , Humanos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Reoperação/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Cabeça do Fêmur/cirurgia , Idoso de 80 Anos ou mais , Adolescente , Desenho de Prótese , Adulto Jovem , Seguimentos , Fatores de Risco
3.
Zhongguo Gu Shang ; 37(4): 381-6, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38664209

RESUMO

OBJECTIVE: CT scans combined with Mimics software were used to measure femoral offset (FO), rotation center height (RCH) and lower leg length discrepancy (LLD) following total hip arthroplasty (THA), and the relationship between FO, RCH and LLD after THA is discussed. METHODS: Retrospective analysis was performed on 40 patients with unilateral THA who met standard cases from October 2020 to June 2022. There were 21 males and 19 females, 18 patients on the left side and 22 patients on the right side, aged range from 30 to 81 years old, with an average age of (58.90 ±14.13) years old, BMI ranged from 17.3 to 31.5 kg·m-2 with an average of (25.3±3.4) kg·m-2. There were 30 cases of femoral head necrosis (Ficat type Ⅳ), 2 cases of hip osteoarthritis (Tönnis type Ⅲ), 2 cases of developmental hip dislocation combined with end-stage osteoarthritis (Crowe type Ⅲ), and 6 cases of femoral neck fracture (Garden type Ⅳ). Three-dimensional CT reconstruction of pelvis was taken preoperative and postoperative, and three-dimensional reconstruction model was established after processing by Mimics software. FO, RCH and LLD were measured on the model. The criteria for FO reconstruction were as follows:postoperative bilateral FO difference less than 5 mm;the standard for equal length of both lower limbs was as follows:postoperative LLD difference less than 5 mm. RESULTS: Bilateral FO difference was positively correlated with LLD (r=0.744, P<0.001). Chi-square test was performed between the FO reconstructed group and the non-reconstructed eccentricity group:The results showed that the isometric ratio of lower limbs in the FO reconstructed group was significantly higher than that in the FO reconstructed group (χ2=6.320, P=0.012). The bilateral RCH difference was significantly negatively correlated with LLD(r=-0.877, P<0.001). There is a linear relationship between bilateral FO difference and bilateral RCH difference and postoperative LLD, and the linear regression equation is satisfied:postoperative LLD=0.038x-0.099y+0.257(x:postoperative bilateral FO difference, y:postoperative bilateral RCH difference; Unit:cm), F=77.993, R2=0.808, P=0.009. CONCLUSION: After THA, LLD increased with the increase of FO and decreased with the increase of RCH. The effect of lower limb isometric length can be obtained more easily by reconstruction of FO. There is a linear relationship between the bilateral FO difference and the bilateral RCH difference after THA and LLD, and the regression equation can provide a theoretical reference for judging LLD.


Assuntos
Artroplastia de Quadril , Fêmur , Desigualdade de Membros Inferiores , Humanos , Masculino , Feminino , Desigualdade de Membros Inferiores/etiologia , Idoso , Pessoa de Meia-Idade , Artroplastia de Quadril/métodos , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Adulto , Fêmur/cirurgia , Tomografia Computadorizada por Raios X , Rotação , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/etiologia
4.
Arthroplast Today ; 27: 101363, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38665390

RESUMO

Background: Nowadays, emphasis is being given to same-day discharge (SDD) following total joint arthroplasty. Unfortunately, despite a high degree of success, there are instances of failed SDD. Therefore, we aim to conduct a systematic review to evaluate factors contributing to failed SDD after total joint arthroplasty. Methods: Pubmed, Scopus, Cochrane, and Google Scholar were searched. The Newcastle Ottawa score was used for the quality assessment of selected studies. All the studies were evaluated through a narrative synthesis. A total of 11 studies evaluating 157,045 patients were selected. The mean age of patients was 62.5 years. Results: Elderly patients (odds ratio [OR] 1.01 to OR 3.13), women (OR 1.63 to OR 2.87), non-white race (OR 1.31 to OR 2.19), hypertension (OR 1.11 to OR 1.41), diabetes (OR 1.25 to OR 4.06), cardiovascular diseases (OR 1.67 to OR 12.06), chronic obstructive pulmonary disease (OR 1.30 to OR 1.96), bleeding disorders (OR 1.32 to OR 1.52), obesity (OR 1.35 to OR 3.30), steroid use (OR 1.23 to OR 1.52), late procedure start time (OR 1.22 to OR 5.16), higher postoperative pain (OR 1.93 to OR 5.85), high American Society of Anesthesiologists score (OR 0.92 to OR 3.50) were major predictors of failed SDD. Conclusions: Through our review, we highlighted that elderly patients, women, non-white race, hypertension, diabetes, cardiovascular diseases, chronic obstructive pulmonary disease, bleeding disorders, obesity, steroid use, late procedure start time, higher postoperative pain, and high American Society of Anesthesiologists score were major predictors of a failed SDD. Many factors evaluated in our study were presented in one or two studies only; therefore, high-quality studies are required to supplement our findings.

5.
Cureus ; 16(3): e56375, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633937

RESUMO

Prosthetic joint infection (PJI) remains a significant complication following joint arthroplasty, necessitating prompt recognition and intervention to optimize patient outcomes. This case report describes a 65-year-old male who presented with persistent pain, swelling, and purulent discharge from the right hip, three years post-bipolar hemiarthroplasty following a road traffic accident. Clinical examination revealed signs suggestive of PJI, prompting surgical intervention with total hip arthroplasty. Postoperatively, the patient experienced resolution of symptoms and satisfactory recovery. This case underscores the challenges associated with infected joint arthroplasty and highlights the importance of a multidisciplinary approach for effective management. Early diagnosis, appropriate surgical intervention, and comprehensive postoperative care are essential for minimizing morbidity associated with PJIs and optimizing patient outcomes.

6.
Cureus ; 16(3): e56350, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633974

RESUMO

Post-traumatic hip arthritis presents a challenging condition characterized by degenerative changes in the hip joint following traumatic injury. Total hip arthroplasty (THA) is a cornerstone in managing this condition, offering significant pain relief, functional improvement, and enhanced quality of life. This comprehensive review aims to synthesize existing literature to elucidate the outcomes of THA in post-traumatic hip arthritis, exploring factors influencing surgical success and identifying areas for further research. Key findings reveal favourable clinical outcomes associated with THA, though considerations such as patient characteristics, surgical techniques, and implant selection impact outcomes. Implications for clinical practice underscore the importance of tailored preoperative assessment and ongoing advancements in surgical approaches and implant technology. Furthermore, opportunities for future research lie in long-term durability studies, patient-reported outcomes assessment, and exploration of innovative surgical techniques. Overall, THA emerges as a promising intervention for post-traumatic hip arthritis, yet continual refinement through research and innovation remains imperative to optimize patient care in this population.

7.
EFORT Open Rev ; 9(4): 264-275, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38579748

RESUMO

Purpose: to systematically review comparative studies reporting revision rates, clinical outcomes, or radiographic outcomes of total hip arthroplasty (THA) using collared versus collarless conventional-length uncemented hydroxyapatite (HA)-coated stems. Methods: In adherence with PRISMA guidelines, a literature search was performed on Medline, Embase, and Scopus. Comparative clinical studies were eligible if they reported outcomes of collared versus collarless uncemented HA-coated stems for primary THA. Two reviewers screened titles, abstracts, and full-texts to determine eligibility; then performed data extraction; and assessed the quality of studies according to Joanna Briggs Institute (JBI) checklist. Results: The search returned 972 records, 486 were duplicates, and 479 were excluded after title/abstract/full-text screening. Three further studies were included from the references of eligible studies and from discussions with subject matter experts, resulting in 11 included studies. The JBI checklist indicated six studies scored ≥7 points and four studies ≥4 points. Pooled data revealed collared stems had significantly lower revision rates (OR = 0.45; 95% CI = 0.31-0.64) and subsidence (MD = -1 mm; 95% CI = -1.6--0.3), but no significant difference in intraoperative complication rates (OR = 0.94; 95% CI = 0.67-1.32) in the short term to mid-term. Unpooled data indicated that collared stems provide equivalent survival, equivalent or better outcomes, and equivalent or lower complication rates. Conclusion: In comparative studies, collared stems have lower revision rates than collarless stems, as well as equivalent or better clinical and radiographic outcomes. Differences could be due to a protective effect that the collar offers against subsidence, particularly in undersized or misaligned stems. Further studies are warranted to confirm long-term results and better understand differences between registry data and clinical studies.

8.
World J Orthop ; 15(3): 293-301, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38596185

RESUMO

BACKGROUND: Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages. Joint arthroplasty is the surgical management of choice in these articulations. Heterotopic ossification and radiolucent lines formation are two frequent problems faced in hip and knee replacements respectively. Some studies show that the usage of pulsed lavage may prevent their formation. AIM: To compare pulsed lavage to standard lavage in joint arthroplasty. METHODS: PubMed, Cochrane, and Google Scholar (page 1-20) were searched till December 2023. Only comparative studies were included. The clinical outcomes evaluated were the heterotopic ossification formation in hip replacements, radiolucent lines formation, and functional knee scores in knee replacements. RESULTS: Four studies met the inclusion criteria and were included in this meta-analysis. Pulsed lavage was shown to reduce the formation of radiolucent lines (P = 0.001). However, no difference was seen in the remaining outcomes. CONCLUSION: Pulsed lavage reduced the formation of radiolucent lines in knee replacements. No difference was seen in the remaining outcomes. Furthermore, the clinical significance of these radiolucent lines is poorly understood. Better conducted randomized controlled studies and cost-effectivity studies are needed to reinforce these findings.

9.
Arthroplast Today ; 27: 101372, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38654888

RESUMO

Background: The impact of amphetamine abuse on total hip arthroplasty (THA) outcomes has yet to be studied. As the rates of methamphetamine abuse continue to rise, understanding the risk profile of this population is imperative. This study aims to determine the risk of major surgical and medical complications for those with amphetamine abuse undergoing THA, with the hypothesis that amphetamine abuse carries increased risk. Methods: A retrospective review was performed with all-claims data files of a large national database querying International Classification of Disease, tenth revision, procedure codes identifying 333,038 primary THA, and 1027 with active amphetamine abuse. Medical and surgical complications including infection, dislocation, implant failure, periprosthetic fracture, and revision, as well as length of hospital stay and 90-day readmission rate, were identified. Univariate analysis compared rates of dependent outcomes. To account for independent variables, logistic regression was performed using age, Charlson comorbidity index, sex, obesity, tobacco use, and alcohol use. The results were presented as odds ratios (OR) and P values with significance set at <0.05. Results: Patients with active amphetamine abuse carried an increased risk of dislocation (OR 1.82, P ≤ .001), infection (OR 2.37, P ≤ .001), mechanical complications (OR 1.64, P ≤ .001), periprosthetic fracture (OR 1.53, P ≤ .05), revision (OR 1.70, P ≤ .001), 90-day readmission (OR 1.79, P ≤ .001), as well as medical complications (1.43, P = .02) compared to those without documented amphetamine abuse. Conclusions: Patients with amphetamine abuse are at increased risk of postoperative surgical and medical complications following THA. We recommend consideration of these risks prior to primary THA in this patient population.

10.
Cureus ; 16(3): e56628, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38646251

RESUMO

INTRODUCTION: This study aimed to evaluate the accuracy of the suture technique, along with the utilization of a spirit-level device which is an instrument designed to indicate whether a surface is horizontal or vertical, in comparison to the conventional supraacetabular pin method and caliper measurement for correcting leg length discrepancy (LLD) during total hip arthroplasty (THA). Materials and methods: Consecutive patients who underwent unilateral primary THA between January 2021 and March 2023 were included in the study. The exclusion criteria were severe flexion and adduction contracture that could affect the accuracy of measurements, a history of lower extremity surgery, the presence of lower extremity deformity, and the absence of postoperative full-length radiographs. Patients were allocated into two groups based on the technique employed for correcting LLD during THA. Group 1 (n=62) consisted of patients evaluated using the suture technique with a spirit-level device, while group 2 (n=75) comprised patients who underwent the supraacetabular pin method with caliper measurement. The distance between the inter-teardrop line and the tip of the lesser trochanter was measured for both hips to assess LLD. RESULTS: The mean preoperative LLD was similar between groups, which was 11.6 ± 9.1 mm in group 1 and 9.5 ± 9.8 mm in group 2 (p=0.191). Postoperatively, group 1 had a significantly lower LLD compared to group 2 (p<0.001). CONCLUSION: According to the results obtained from this study, the use of a suture technique in conjunction with a spirit-level device to achieve a consistent leg position is an effective method for correcting LLD during THA.

11.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
12.
J Funct Morphol Kinesiol ; 9(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38651421

RESUMO

Total hip arthroplasty is indubitably one of the most performed operations worldwide. On the other hand, especially in the western world, the average age that women get pregnant has raised confoundedly. Consequently, a steadily increasing number of women become pregnant after they had hip arthroplasty surgery, with copious potential implications. The amount of knowledge on this particular field is considered inadequate in the existing literature. This paper aims to augment clinicians understanding surrounding this topic. A systematic literature review was conducted in accordance with the PRISMA guidelines. Papers from various computerized databases were scrutinized. Article selection was carried out by three authors independently employing specific pre-determined inclusion and exclusion criteria, while disagreements were elucidated with the contribution of other authors. A patently limited number of research articles were detected from our rigorous literature review, with only 12 papers meeting the inclusion criteria. The vast majority of studies were small-scale and examined confined population groups. Most studies had been performed in Finland, utilizing data from nationwide registries. Women with previous history of total hip arthroplasty feature increased rates of c-section delivery, although vaginal labor can be attempted with certain precautions. Hip implants' survival does not appear to be affected from gestation, which is predominately well-tolerated from these women. Metal ion circulation in mothers' blood has not been proven to trigger substantial complications concerning either mothers or offspring. It can be considered safe for women with such medical history to get pregnant; however, further multinational studies and pertinent research on this field are vital to attain more solid inferences.

13.
Antibiotics (Basel) ; 13(4)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38667042

RESUMO

Periprosthetic joint infection (PJI) is a serious complication after joint arthroplasty. PJI screening and conventional cultures may be inconclusive. Sonication fluid culturing stands out as a valuable adjunct technique for PJI diagnosis. This study aims to determine the clinical relevance of routine sonication for all (a)septic revisions. All patients who underwent (partial) hip or knee revision arthroplasty between 2012 and 2021 were retrospectively reviewed. We formed three groups based on the European Bone and Joint Society PJI criteria: infection confirmed, likely, and unlikely. We analyzed clinical, laboratory, and radiological screening. Sensitivity and specificity were calculated for synovial fluid (preoperative), tissue, and sonication fluid cultures. We determined the clinical relevance of sonication as the percentage of patients for whom sonication confirmed PJI; 429 patients who underwent (partial) revision of hip or knee arthroplasty were included. Sensitivity and specificity were 69% and 99% for synovial fluid cultures, 76% and 92% for tissue cultures, and 80% and 89% for sonication fluid cultures, respectively. Sonication fluid cultures improved tissue culture sensitivity and specificity to 83% and 99%, respectively. In 11% of PJIs, sonication fluid cultures were decisive for diagnosis. This is applicable to acute and chronic infections. Sonication fluid cultures enhanced the sensitivity and specificity of PJI diagnostics. In 11% of PJI cases, causative pathogens were confirmed by sonication fluid culture results. Sonication fluid culture should be performed in all revision arthroplasties.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38668775

RESUMO

PURPOSE: Interest in bilateral total hip arthroplasty (THA) has been increasing over the past decade. This study aims to compare postoperative local and systemic complications, hospital readmissions, and satisfaction assessment in patients undergoing simultaneous versus staged bilateral THA. METHODS: A retrospective observational study was conducted among patients who underwent simultaneous or staged bilateral THA between 2017 and 2020. Data on perioperative parameters, local and systemic complications, and 30-day hospital readmissions were collected. Patient satisfaction was assessed using Forgotten Joint Score (FJS). The comparison of continuous variables with normal distribution of variance was performed by ANOVA; for variables with abnormal distribution, the nonparametric test Mann-Whitney U was adopted. The distribution of dichotomous variables was analyzed by chi-square test, and statistical significance was calculated by Fisher exact test. RESULTS: The study included 199 patients, of whom 156 underwent staged and 43 simultaneous bilateral THA. A total of 44 patients developed complications (21 systemics, 12 locals, and 20 postoperative anemia). There were no significant differences regarding local (simultaneous 5% vs. staged 6%; p = 0.999) or systemic complications (simultaneous 14% vs. staged 10%; p = 0.408). Only the incidence of postoperative anemia was significantly higher in simultaneous group compared with staged group (p = 0.003). There were no significant differences in FJS between the two groups (p = 0.258). CONCLUSION: No differences in local or systemic complications nor readmission rates were observed following simultaneous or staged bilateral THA. Simultaneous bilateral THA is non-inferior to staged implants in terms of safety and patient satisfaction.

15.
Curr HIV Res ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38638043

RESUMO

BACKGROUND: In the post-epidemic era, Acquired Immune Deficiency Syndrome (AIDS) remains one of the most prevalent and detrimental infectious diseases worldwide. The incidence of osteonecrosis of the femoral head (ONFH) in AIDS patients is 100 times higher than that in healthy individuals. Although Total Hip Arthroplasty (THA) is ultimately necessary for most patients, there is still a dearth of evidence regarding its safety and efficacy in Chinese AIDS patients. METHODS: The clinical data of 49 patients who met the inclusion and exclusion criteria were retrospectively analyzed. Simultaneously, we categorized patients whose hemoglobin and albumin met a specific threshold as the optimized group and performed group comparisons. RESULTS: There are statistical differences in Harris score and VAS score pre- and post-operation, with a low overall complication rate. Notably, no disparities were observed between the optimized group and the partial optimized group in terms of overall conditions, laboratory examination indicators, severity of ONFH, surgical outcomes, surgical complications, pain perception or functional limitations. Furthermore, no correlation was found between CD4+ T lymphocytes and hemoglobin levels, albumin levels, white blood cell count, or platelet count. CONCLUSION: THA is safe and effective in Chinese AIDS patients with ONFH. However, optimal treatment has limited efficacy in AIDS patients undergoing THA for ONFH. The reconsideration and evaluation of the predictive value of CD4+ T lymphocytes for postoperative complications in joint replacement procedures is warranted.

16.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632066

RESUMO

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Masculino , Feminino , Humanos , Idoso , Falha de Prótese , Reoperação , Estudos Retrospectivos , Inteligência Artificial , Seguimentos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Complicações Pós-Operatórias , Luxações Articulares/cirurgia
17.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 461-465, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632067

RESUMO

Objective: To explore the method of accurately estimating the acetabular cup prosthesis coverage rate (hereinafter referred to as "cup coverage rate") in total hip arthroplasty (THA) based on X-ray films, and to determine the effective parameters that can be used to estimate the cup coverage rate. Methods: The three-dimensional printed pelvic models were established based on CT data of 16 healthy pelvis, and the acetabular prosthesis were implanted according to conventional THA procedure. The length and width of the uncovered area of the acetabular cup prosthesis were measured by a modified X-ray recording method with a rotating C-arm X-ray machine, and the cup coverage rate was calculated. Then the differences among the traditional anteroposterior X-ray recording method, the modified method, and actual measurement on pelvic model were statistically analyzed. The correlation between the area of the uncovered area of the prosthesis and its width and length was analyzed by using multiple linear regression analysis. Results: The cup coverage rates of traditional method, modified method, and actual measurement were 78.22%±3.36%, 86.74%±3.61%, and 89.62%±2.62%, respectively, with significant differences ( P<0.05). The results of multiple linear regression analysis showed that the width and length were positively linear with the uncovered area of the prosthesis, and the regression equation was as follows: uncovered area of the prosthesis=-21.192+0.248×width+0.140×length, and the coefficient of determination R 2=0.857, P<0.001. Conclusion: Compared with the traditional method, the modified method can more accurately evaluate the cup coverage rate during THA, and the width of the uncovered area of the prosthesis can be used as an effective reference for the cup coverage rate.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Filme para Raios X , Tomografia Computadorizada por Raios X/métodos
18.
J Arthroplasty ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38640966

RESUMO

BACKGROUND: Modular dual mobility (DM) bearings have a junction between a cobalt chrome alloy (CoCrMo) liner and titanium shell, and the risk of tribocorrosion at this interface remains a concern. The purpose of this study was to determine whether liner malseating and liner designs are associated with taper tribocorrosion. METHODS: We evaluated 28 retrieved modular DM implants with a mean in situ duration of 14.6 months (range, 1 to 83). There were two manufacturers included (12 and 16 liners, respectively). Liners were considered malseated if a distinct divergence between the liner and shell was present on postoperative radiographs. Tribocorrosion was analyzed qualitatively with the modified Goldberg Score (mGS) and quantitatively with an optical coordinate-measuring machine. An acetabular shell per manufacturer was sectioned for metallographic analysis. RESULTS: There were six implants (22%) that had severe grade 4 corrosion, six (22%) had moderate grade 3, 11 (41%) had mild grade 2, and five (18.5%) had grade 1 or no visible corrosion. The average volumetric material loss at the taper was 0.086 ± 0.19 mm3. There were seven liners (25%) that had radiographic evidence of malseating, and all were of a single design (P = 0.01). The two liner designs were fundamentally different from one another with respect to the CoCrMo alloy type, taper surface finish, and shape deviations. Malseating was an independent risk factor for increased volumetric material loss (P = 0.017). CONCLUSION: Dual mobility tribocorrosion with quantifiable material loss occurred more commonly in malseated liners. Specific design characteristics may make liners more prone to malseating, and the interplay between seating mechanics, liner characteristics, and patient factors likely contributes to the shell/liner tribocorrosion environment.

19.
J Arthroplasty ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38640968

RESUMO

BACKGROUND: Revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) tremendously burden hospital resources. This study evaluated factors influencing perioperative costs, including emergency department (ED) visits, readmissions, and total costs-of-care within 90 days following revision surgery. METHODS: A retrospective analysis of 772 revision TKAs and THAs performed on 630 subjects at a single center between January 2007 and December 2019 was conducted. Cost data was available from January 2015 to December 2019 for 277 patients. Factors examined included comorbidities, demographic information, pre-operative Anesthesia Society of Anesthesiologists score, implant selection, and operative indication using mixed-effects linear regression models. RESULTS: Among 772 revisions (425 THA and 347 TKA), 213 patients required an ED visit, and 90 required hospital readmission within 90 days. There were 22.6% of patients who underwent a second procedure after their initial revision. Liver disease was a significant predictor of ED readmission for THA patients (multivariable OR [odds ratio]: 3.473, P = 0.001), while aseptic loosening, osteolysis, or instability significantly reduced the odds of readmission for TKA patients (OR: 0.368, P = 0.014). In terms of ED visits, liver disease increased the odds for THA patients (OR: 1.845, P = 0.100), and aseptic loosening, osteolysis, or instability decreased the odds for TKA patients (OR: 0.223, P < 0.001). Increased age was associated with increased costs in both THA and TKA patients, with significant cost factors including congestive heart failure for TKA patients (OR: $7,308.17, P = 0.004) and kidney disease for THA patients. Revision surgeries took longer than primary ones, with TKA averaging 3.0 hours (1.6 times longer) and THA 2.8 hours (1.5 times longer). CONCLUSION: Liver disease increases ED readmission risk in revision THA, while aseptic loosening, osteolysis, or instability decreases it in revision TKA. Increased age and CHF are associated with increased costs. These findings inform postoperative care and resource allocation in revision arthroplasty.

20.
Fam Pract ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641558

RESUMO

INTRODUCTION: There are currently different management guidelines for patients undergoing elective total hip arthroplasty (THA) or total knee arthroplasty (TKA) that are on long-term anticoagulation. The timing of discontinuation and restarting the anticoagulation is challenging during the postoperative care, which often involves general practitioners and physiotherapists. METHODS: The systematic review followed the PRISMA guidelines and included 3 databases: PubMed/MEDLINE, EMBASE, and Web of Science Core Collection. It was registered in the International Prospective Register for Systematic Reviews and Meta-analysis (PROSPERO) under the registration number: CRD42023408906. The risk of bias assessment was performed using the Methodological index for non-randomized studies (MINORS) criteria. RESULTS: Six retrospective studies involving 727 patients with therapeutic anticoagulation (1,540 controls) for elective THA, TKA and revision arthroplasty have been included. The follow-up ranged from 30 days to 1 year postoperatively. All studies evaluated outcomes of warfarin therapeutic anticoagulation versus prophylactic dosages of one or more of the following: warfarin, aspirin, low-molecular-weight heparin (LMWH) and unfractionated low-dose heparin (UFH). One study did not discontinue therapeutic anticoagulation. Two studies reported no significant differences in complications between groups, whilst 3 studies had significantly higher rates of superficial wound infections, revision surgeries, postoperative haematomas, and prosthetic joint infections (PJI). CONCLUSION: Different anticoagulation-related perioperative management strategies achieve different outcomes following elective arthroplasty in patients with therapeutic chronic anticoagulation. There is contradictory evidence regarding the need for the discontinuation of therapeutic warfarin. Retrospective data showed that individual risk stratification with multi-modal prophylaxis resulted in minimal complications. LEVEL OF EVIDENCE: Systematic Review of Level III studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...